DCYSCORE¶
Summary
Associates selected scoring detectors of given estimator type with user-defined decay times or with combined prompt-decay particle scoring. In the first case, see warning in Note 1 below. Also needed for scoring when the source is a radioactive isotope.
See also DCYTIMES, IRRPROFIle, RADDECAY, RESNUCLEi
- WHAT(1) > 0.0:
- = –1.0
: if option
RADDECAYhas been requested withWHAT(1) > 1.0, i.e. for radioactive decays activated in semi-analogue mode, the detectors defined byWHAT(4)–WHAT(6)will score both prompt and radioactive decay particles. See Note 6, and 7 for the case where the source has been defined as a radioactive isotope.- = 0.0 :
no scoring
- Default
= 0.0
- WHAT(2)
– WHAT(3): not used
- WHAT(4) :
- lower index bound (or corresponding name) of detectors of type
SDUMassociated with the specified cooling time (ifWHAT(1) > 0.) or with combined prompt-decay particle scoring (ifWHAT(1) = –1.)(“From detector ``WHAT(4)`` of estimator type ``SDUM``…”) - Default
= 1.0
- WHAT(5) :
- upper index bound (or corresponding name) of detectors of type
SDUMassociated with the specified cooling time or with combined prompt-decay particle scoring(“…to detector ``WHAT(5)`` of estimator type ``SDUM``…”) - Default
=
WHAT(4)- WHAT(6) =
- step length in assigning indices(“…in steps of ``WHAT(6)`` ”)
- Default
= 1.0
- SDUM
: identifies the kind of estimator under consideration:
EVENTBIN, RESNUCLEi, USRBDX, USRBIN, USRCOLL, USRTRACK, USRYIELD- Default
: no default!
- Default
(option
DCYSCOREnot requested): no particles originated from radioactive decay are scored, in whatever mode decay is being calculated (see Notes 5, 6 and 7 below).
Notes
- Warning: when the
DCYSCOREoption is applied to a detector withWHAT(1) > 0.0, all quantities are expressed per unit time (in seconds). For instance, theRESNUCLEi estimator will output Bq, dose estimators will provide dose rate, etc..IfWHAT(1) = –1., all quantities are normalized per unit primary weight, or per decay if the source has been defined as a radioactive isotope. The cooling time index indicated by
WHAT(1) > 0.must be one of those defined by means of optionDCYTIMES. USRBIN andEVENTBIN detectors are similar, therefore they are part of the same index sequence; this has to be taken into account for the numbering of the detectors. The same holds forUSRTRACK andUSRCOLL detectors.- The scoring of decay radiation in “activation study” non-analogue mode (
WHAT(1) > 0.0, see Note 1 ofRADDECAY) is different from all the rest: decay particles are transported once, and a factor is applied at scoring time depending on the decay time associated to each detector.This factor accounts for the buildup and decay of the parent nucleus at the specified decay time. This factor is not available in user routines such asFLUSCWandCOMSCW (FLUSCW: weighting fluence, current and yield,COMSCW: weighting deposited energy or stars) If radioactive decay has been requested in “activation study” mode (command
RADDECAYwithWHAT(1) = 1) particles originated from radioactive decay are scored at cooling times requested withDCYTIMES. CommandDCYSCORE, called withWHAT(1) > 0.0, is used to associate a detector of typeSDUMto a particular cooling time. IfDCYSCOREis not present, no particles originated from radioactive decay can be scored.If radioactive decay has been requested in “semi-analogue” mode (Monte Carlo sampling: command
RADDECAYwithWHAT(1) > 1.0), particles originated from radioactive decay are scored by the selected detectors of typeSDUMtogether with prompt particles, providedDCYSCOREis issued withWHAT(1) = –1.0. IfDCYSCOREis not present, no particles originated from radioactive decay can be scored, and any detector will score only prompt particles.If the source has been defined as a radioactive isotope (see command
BEAMwithSDUM = ISOTOPE), the radioactive decay must be activated in semi-analogue mode (see Note 1 ofRADDECAY), and thereforeWHAT(1)ofDCYSCOREmust be = –1.0. This can be considered as a special case of the situation described in Note 6, where only decay particles are present, and no prompt particles. Also in this case, ifDCYSCOREis not present no particles originated from radioactive decay can be scored. And since no prompt particles are present, no scoring at all can take place.
Example, for a number-based input:
*...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+...
DCYTIMES 86400. 172800.
DCYSCORE 1. 0. 0. 4. 8. 2.USRBIN
DCYSCORE 2. 0. 0. 1. 5. USRTRACK
* Two cooling times have been defined. Binnings no. 4, 6 and 8 will be
* associated to the first cooling time (one day), and track-length detectors
* no. 1, 2, 3, 4 and 5 will be associated to the second cooling time (2 days)
The same example, in a name-based input:
DCYTIMES 86400. 172800.
DCYSCORE 1. 0. 0. binning4 binning8 2.USRBIN
DCYSCORE 2. 0. 0. trakDet1 trakDet5 USRTRACK